Photoneo MotionCam-3D Color

Specific setup instructions for setting up Photoneo sensor.

Overview

To setup Photneo sensor one needs to:

  • setup hardware connections (data and power)

  • in Photoneo Phoxi Control software

    • set IP address for the sensor

    • note the serial number for use on Cortex

  • set IP address in the same network on Cortex device

  • in Cortex CommandConsole

    • add the sensor and set at least the serial number

  • extract internal calibration from device and put it on Cortex device

Hardware Connections

Photoneo may use PoE (Power over Ethernet) standard to supply data and power to sensor with single cable. In this scenario PoE injector is used:

  • connect Ethernet cable to data+power port on injector and M12-X cable to Photoneo sensor

  • connect Ethernet cable from data port on the PoE injector to the PC or network device (like switch)

  • connect power supply to PoE injector

In case of doubts consult Photoneo documentation available from the manufacturer.

Setting up the IP Address (Photoneo)

To setup IP address for the sensor download and install PhoXi Control software from the manufacturer:

Make sure that sensor is connected to the same network as device with PhoXi Control and powered on.

  • take note of the ID of the sensor (FTR-057), it will be necessary in the later steps

  • select the sensor in PhoXi Control

  • select the Configure option

  • select the Static IP

  • set the IP for the device like (here 192.168.2.2)

  • you don't need to fill in Gateway and DNS

  • select Apply

Setting up IP Address (Cortex)

Set IP address in the same network as Photoneo for Cortex device network interface that will be used with Photoneo sensor. In the example here it would be 192.168.2.x IP address.

It is recommended to use dedicated network interface for Photoneo as the device streams huge amounts of data over network.

Configuring Sensor in Command Console

Add Photoneo sensor in Command Console and modify at least the Serial Number field.

  • the value has to Photoneo-<ID noted from Phoxi Control>

    • in our example we noted FTR-057

      • so the Serial Number field should be set to Photoneo-FTR-057

Extracting Photoneo Sensor Calibration

At this point you should be already able to connect to the sensor and get some data from it. Without extracting calibration from device the 3D geometry will not be correct (default calibration differing from your specific unit is used).

You may find instructions for extracting internal calibration from the sensor at the bottom of:

Extracting the calibration is technically involved and it is recommended to contact Extend Robotics to support you in the process unless you are comfortable with building C++ programs and using CLI tools.

Finally put extracted calibration in extend_calibration directory on the Cortex device.