Photoneo MotionCam-3D Color
Specific setup instructions for setting up Photoneo sensor.
Overview
To setup Photneo sensor one needs to:
setup hardware connections (data and power)
in Photoneo Phoxi Control software
set IP address for the sensor
note the serial number for use on Cortex
set IP address in the same network on Cortex device
in Cortex CommandConsole
add the sensor and set at least the serial number
extract internal calibration from device and put it on Cortex device
Hardware Connections
Photoneo may use PoE (Power over Ethernet) standard to supply data and power to sensor with single cable. In this scenario PoE injector is used:
connect Ethernet cable to data+power port on injector and M12-X cable to Photoneo sensor
connect Ethernet cable from data port on the PoE injector to the PC or network device (like switch)
connect power supply to PoE injector

In case of doubts consult Photoneo documentation available from the manufacturer.
Setting up the IP Address (Photoneo)
To setup IP address for the sensor download and install PhoXi Control software from the manufacturer:
Make sure that sensor is connected to the same network as device with PhoXi Control and powered on.
take note of the ID of the sensor (FTR-057), it will be necessary in the later steps
select the sensor in PhoXi Control
select the
Configureoption

select the Static IP
set the IP for the device like (here 192.168.2.2)
you don't need to fill in Gateway and DNS
select
Apply

Setting up IP Address (Cortex)
Set IP address in the same network as Photoneo for Cortex device network interface that will be used with Photoneo sensor. In the example here it would be 192.168.2.x IP address.
Configuring Sensor in Command Console
Add Photoneo sensor in Command Console and modify at least the Serial Number field.
the value has to Photoneo-<ID noted from Phoxi Control>
in our example we noted
FTR-057so the
Serial Numberfield should be set toPhotoneo-FTR-057

Extracting Photoneo Sensor Calibration
At this point you should be already able to connect to the sensor and get some data from it. Without extracting calibration from device the 3D geometry will not be correct (default calibration differing from your specific unit is used).
You may find instructions for extracting internal calibration from the sensor at the bottom of:
Finally put extracted calibration in extend_calibration directory on the Cortex device.